Shopping cart is empty.
 

Daikin - Single Split

Product Code: FTXS25J


  • Price (inc GST): ^

    ^Conditions Apply - see Important Notes below

  • Additional Options (tick if needed)


  • Make an Enquiry
Daikin - Single Split

These units have a sleek flat panel design, allowing them to be coordinated easily within any decor.

#

Important Points about your Split System Air Conditioner Installation

  • The displayed price includes:
    • Installation of a wall hung unit, back to back on an external wall with internal head unit within 3 metres of the ground mounted external compressor unit.
    • Installation of gas/liquid lines (3 metres) from the internal head unit to the external compressor unit including a maximum of 2 metres pipe capping.
    • Installation of the external unit in a location that meets the manufacturer's requirements. Need a suitable hard surface on the ground, otherwise additional charges may apply.
    • All certificates of compliance as required.
    • Wiring of a new individual circuit back to the meter box (maximum 15 metres). Also includes an external isolation switch and a circuit breaker (if required for the switchboard).
    • Removal and disposal of all wall hung split air-conditioning systems packaging.
  • Conditions of installation:
    • Multi-head and non standard back to back installations will require a site check.
    • Installation vehicle, equipment and installation team must have clear and unhindered access to the site and internal/external location where indoor/outdoor units are to be mounted.
    • Any travel, accommodation, additional fees and charges associated with installations in excess of 40kms from the Fallon Services Offices, will be charged to the customer as an additional cost.
    • House wiring/power supply/switchboard must be in accordance with Australian standards and Manufacturer specifications. Additional charges may apply for non-compliant electrical wiring/switchboards and cable runs in excess of 15 metres.
  • Any additional charges will be discussed and agreed upon prior to installation.

#

Features:

  • 24-Hour On/Off Timer - The timer can be preset to start and stop the air conditioner at any time within a 24 hour period. Once the times are set, the air conditioner can be operated for a period by simply pressing the ON or OFF timer buttons.
  • 3-D Airflow - Combines Vertical and Horizontal Auto Swing to circulate cool/warm air to the corners of large spaces.
  • Air Purifying Filter with Photocatalytic Deodorising Function - This filter traps microscopic particles and decomposes odours. The filter can be used for approx. 3 years if periodic maintenance is performed.
  • Anti-Corrosion - The special anti-corrosion coating on the outdoor unit heat exchanger ensures greater resistance to salt damage and atmospheric pollution.
  • Auto Fan Speed - To reduce operating noise, the fan speed is automatically controlled by the microprocessor to suit the thermostat setting and room temperature.
  • Automatic Operation - For unattended year round comfort, this function allows the unit to automatically switch between heating and cooling modes as required.
  • Auto-Restart - The unit memorises the operation mode, air flow setting, temperature and timing settings so that, should there be a power failure when the unit is in operation, it will automatically return to the same operating conditions when the power is restored.
  • Comfortable Mode - The new flap changes the delivery angle to horizontal for cooling and vertical for heating operation, to prevent cold or warm air from directly blowing directly onto your body.
  • Econo Mode - Econo Mode reduces the maximum operating current and power consumption of the outdoor unit by approximately 30% during start-up. This provides outstanding energy savings and convenience when using multiple air conditioners and electrical devices simultaneously.
  • Horizontal Auto-Swing (left and right) - The wide-angle louvres automatically direct horizontal airflow to achieve a uniform temperature throughout the room.
  • Hot Start - When the heating operation starts or when the unit changes from cooling to heating there is no cold draught released into the room.
  • Indoor Unit On/Off Switch - A convenient On/Off Switch on the indoor unit allows you to start up the system even if you have misplaced the remote controller or the remote controller batteries are exhausted.
  • Indoor Unit Quiet Operation - Sound levels are reduced for quieter and more gentle heating and cooling.
  • Intelligent Eye - The intelligent eye is an infrared sensor with the ability to sense human movement in a room. When you are in the room, the air conditioner operates normally. If you leave the room for more than 20 minutes the air conditioner automatically changes to energy saving operation.
  • Inverter Powerful Operation - Pushing the POWERFUL button on the remote controller gives you a 10% boost in cooling power for a 20 minute period, even if the unit is already operating at high capacity.
  • LCD Wireless Remote Control - The remote controller puts comfort at your finger tips. Frequently used buttons are instantly accessible while other pre-set buttons are under the cover of the remote (except for FVY models). A large liquid crystal panel makes it easy to read the settings and the On/Off button has raised dots so that you can feel it in the dark.
  • Night Quiet Mode - Outdoor unit operating sound levels are automatically decressed by 3dB from the rated operation sound when the outdoor temperature has dropped by 6°C from the maximum temperature recorded during the day.
  • Outdoor Unit Quiet Operation - Daikin's new "Outdoor Unit Silent Operation" function cuts operating sound levels for the outdoor unit by 2dB, simply by pushing a button.
  • Power-Airflow Dual Flaps - This unique system directs warm air to the floor in winter and cool air upwards in summer for maximum efficiency and comfort. The large flap governs airflow direction while the small flap (or diffuser) swings, producing fine air currents that help circulate the air around the room.
  • Programme Dry Function - This function automatically reduces the level of humidity rather than room temperature.
  • Self Diagnosis - In the event that a problem develops with the unit, malfunction codes are displayed on the liquid crystal panel of the remote controller for fast and easy maintenance.
  • Vertical Auto-Swing (up and down) - The small flap in the indoor unit automatically swings up for finely tuned adjustments of the air current. When the unit is switched off the louvre closes automatically.
  • Weekly Timer - The NEW Weekly Timer Function makes it easy to enter up to four settings per day for each day of the week. The Weekly Timer Function not only allows you to program on and off time, but also the desired temperature.
  • Wide Angle Lourves - Wide angle lourves with their innovative curved design, provide air flow coverage to effectively cool/heat, no matter where the indoor unit is placed in the room.
  • Wipe-Clean Flat Panel - The smooth surface allows models to be cleaned simply and easily with a cloth. The front panel can be removed for a more thorough clean.

Specifications:

Unit
Indoor Unit FTXS25J2VMA
Outdoor Unit RXS25JVMA
Rated Capacity
Cool (KW) 2.5
Heat (KW) 3.4
Capacity Range
Cool (KW) 1.3-3.2
Heat (KW) 1.3-4.7
Indoor Air Flow
Cool (l/s) 162
Heat (l/s) 175
Indoor Fan Speeds
5 steps, quiet, automatic
Energy Label Star Rating
Cool 3.0
Heat 3.0
Front Panel Colour
White
Power Supply
1 phase, 220-240, 50Hz
Power Input (min-rated-max)
Heat (kW) 0.31-0.79-1.29
Cool (kW) 0.32-0.58-0.81
C.O.P
4.31/4.30
Dimensions (H x W x D)
Outdoor (mm) 550 x 765 x 285
Indoor (mm) 295 x 800 x 215
Weight
Outdoor (kg) 34
Indoor (kg) 9
Compressor Type
Hermetically sealed swing type
Refrigerant
R410A
Maximum Pipe Length
20
Maximum Level Difference
15
Refrigerant Pipe Size
Drain (mm) 18
Liquid (mm) 6.4
Gas (mm) 9.5
Operating Range (Outdoor Temp)
Cooling CDB 10 to 46
Heating CWB -15 to 20
Indoor Sound Level
Heat (dBA) 39/34/28/25
Cool (dBA) 38/32/25/22
Outdoor Sound Level
Cool (dBA) 46/43
Heat (dBA) 47/44
EPA Sound Power Level
62